CashFlow
952X / 952Xe / 9510 User Guide
MEI., 2005 Page 12 Rev: G2
Machine Interface Connector (8)
This 17-way connector provides power to the validator. This connector carries the coin
inhibit and coin outputs signals to and from the machine.
The connector provides the following input and outputs signals:
• Supply Voltage Input (12 volts)
• A to F Coin Outputs (output signal)
• A to F Coin Inhibits (input signal)
• Coin Output Common (input signal)
• Output Mode (input signal)
This connector is not available on the CF9510.
Pre-Gate Strobe and Directional Strobes (9)
The pre-gate stobe detects obstructions around the accept gate. If an obstruction is detected
then coin acceptance is inhibited until the obstruction is cleared.
Directional strobes detect unauthorised entry of a coin for example, a coin or token entering
through the bottom of the Unit.
Reject Lever (10)
The reject lever has two uses: -
• To clear coins jammed in the validators coin path
• To confirm programming operation
Separator Connector (11)
CF952X/CF952Xe
This connector is used to connect the validator to the separator on the CF952X and
CF952Xe series.
CF9510
On the CF9510, this connector is used as the STD124 Open-collector Parallel interface. It
provides the following input/output signals :
• Supply Voltage Input (24Vnom)
• A to F Coin Outputs (output signal)
• A to F Coin Inhibits (input signal)
• Escrow Return Signal (output signal)
• All Inhibit signal (input signal)