MAINTENANCE
5-7
MA-5052-ENG MACRO SERIES MELTER MANUAL
Recommended lubricants
Brand Type of grease
IP Telesia Compound A
SHELL Tivela Compound A
MOBIL Glygoyle Grease 00
Brand Type of oil
KLÜBER Klübersynth GH 6-220
SHELL Tivela Oil S 220
MOBIL Glygoyle 30
Thermostats maintenance
If one of the two existing thermostats is deactivated, follow these instructions
to reset them:
1. Remove the side plate, as shown in the image.
2. Lift the insulating blanket and locate the thermostats.
3. After the blanket has been lifted off the thermostats, identify the
thermostat that has been deactivated and press its corresponding
button to reset it (see Figure).