[CE] VENT Vents the “Measure/Control” pressure port to atmosphere.
[+] HELP Displays instrument name, software version, chassis serial
number and full scale range.
[–] SERIAL Provides a way to set the parameters to be used with RS-232
communications.
Address Termination Character Data Format
Baud Single/Multi Drop
[2nd] 2nd Toggles keypad between numeric and mode functions.
POWER UP!
You can confirm that your PCS 400 is operational
right now. Simply apply power to the power con-
nector on the rear of the instrument, remove any
plastic plugs from the PRESSURE and REFER-
ENCE ports and turn the power switch ON. When
the PCS 400 is turned on it goes through an initiali-
zation process which includes scanning the inter-
nal configuration for file code errors.
About one minute after power is applied the full
display will come on. With no pressure connected,
an absolute instrument of sufficient range will dis-
play atmospheric pressure, while a gauge instru-
ment will display at or very near zero pressure. In
any case the pressure will be displayed in the
measurement units that were specified when the
instrument was ordered.
This confirms that the unit is ready to use. If this
is your first time to use a PCS 400 please review the
Warnings and Cautions information inside the
front cover. Then take the time to familiarize your-
self with the Installation and Operation sections of
this manual and the ‘Menu Tree’ provided there. Te
tree illustrates the command structure and the
functions available from the front panel keypad.
MENSOR SERVICE PLUS
If you have problems using your PCS 400 and you
don’t find the answer in your manual, contact
Mensor at 1.800.984.4200 (USA only), or
1.512.396.4200 for personal assistance, or at any
of the on-line addresses listed in the front of the
manual. We are ready to help.
Mensor’s concern with the welfare of this instru-
ment is not limited to the warranty period. We
provide complete repair services beyond the war-
ranty, as explained in Section 5, Maintenance.
CALIBRATION SERVICES
In addition to servicing our own products Mensor
can perform a complete pressure calibration serv-
ice, up to 20,000 psi, for all of your pressure
instruments. This service includes a Calibration
Certificate and a record of traceability to the pres-
sure standards of the National Institute of Stand-
ards and Technology (NIST).
ACCREDITATIONS
MensorCorp.isregisteredtoBSENISO
9001:2000. The calibration program at Mensor is
accredited by A2LA, as complying with both the
ISO/IEC FDIS 17025:1999 and the ANSI/NCSL
Z540-1-1994 standards.
PCS 400 EVOLUTION
Since its introduction in the PCS 400 has undergone
a continuous process of evolution. Many changes
have been in response to special application re-
quirements expressed by our customers. Once they
are designed these ‘specials are either incorpo-
rated into the standard system, or made available
as options to other users with similar require-
ments. All customers are welcome to discuss their
unique requirements. We may already have a solu-
tion, or we can provide one.The system has proven
to be extremely flexible in this way because of the
modularity of both the software and the hardware.
INTRODUCTION PCS 400
1-6 www.mensor.com