4.2 Remote control commands
756/831 KF Coulometer, Instructions for Use
84
mplist, param, calc, C-fmla, def, statistics, smpl data,
silo, scalc full, scalc srt, config, user method, all, ff
$G sends the selected report to the COM which is set in
&Config.PeriphUnit.RepToComport:
result: Result report of the last completed determination.
water crv: Mass of water in ug vs. time
rate crv: Rate in ug/min vs. time
meas crv: Potential vs. Time
comb: Mass of water in ug & rate in ug/min vs. time
mplist: Measuring point list of the running determination.
param: Parameter report of the current method. During a running determi-
nation only "live"-parameters are accessible.
calc: Calculation report of the current method.
C-fmla: Contents of the <C-fmla> key.
def: Contents of the <def> key.
statistics: Statistics table with the individual results.
smpl data: Current sample data.
silo: Contents of the silo memory.
scalc full: Full report of the silo calculations.
scalc srt: Short report of the silo calculations.
config: Configuration report.
user method: Contents of the method memory.
all: All reports.
ff: Form feed on printer.
Reports which are sent from the Coulometer are marked with space (ASCII
32) and ' at the beginning. Then an individual identifier for each report follows.
4.2.2.64. Info.Checksums $G
Info.Checksums.ActualMethod read only
The checksums can be used to identify the content of a file unequivocally,
e.g. files with identical content have identical results of the checksums. An
empty file has checksum "0". The calculation of the checksums is triggered
with $G.
.ActualMethod: Result of the checksum of the current method in the working
memory. Identical methods with different method names have the
same results of the checksum.
4.2.2.65. Info.DetermData $G
Info.DetermData.Write ON, OFF
Determination data in hexadecimal format.
.Write: With "ON", the following nodes can be overwritten:
&Info.TitrResults.Var.C4X (X = 0...5) and &Mode.Name.
4.2.2.66. Info.TitrResults.RS.1.Value read only
etc., up to .9
Info.TitrResults.EP.V read only
Info.TitrResults.EP.Meas read only
Info.TitrResults.Var.C40 read only/read+write
etc., up to .C45
.RS: Values of the calculated results.