Operating Instructions - Synchroprint 3000 (Manual-Registration Version)
________________________________________________________________________________
Operating Instructions - Synchrprint 3000 (Manual-Registration Version) V1-1 Page 48 of 49
Task
Frequency
Comment/Action
Check
inspection glass
on water
separator/trap
Daily
The inspection glass of the water separator/trap must be
checked for condensed water. The level must not exceed
the red mark; otherwise the automatic relief aperture may
become clogged or defective.
Clean
automatic relief
aperture
Monthly
The entire water separator/trap is attached to the pressure
regulator with a bayonet lock. Take off the water
separator/trap and clean the automatic relief aperture.
Inspection glass
Water
separator/trap

Table of Contents