Why booster cylinder doesn’t work in MHM SYNCHROPRINT 5000 Industrial Equipment?
J
Johnny MorrowAug 30, 2025
The booster cylinder might not work if there is no air pressure at the booster cylinder. This could be due to incorrect adjustment of the lower pressure regulator or an active lower pressure stop cock.
S
Stephen JohnsonAug 29, 2025
Why the indexer doesn’t work in MHM SYNCHROPRINT 5000 Industrial Equipment?
J
jason26Aug 29, 2025
The indexer might not work if the supply cable of the tablet is not connected. Connect the supply cable to the tablet.
P
Peter BarnettAug 28, 2025
What does error #0002 mean on MHM SYNCHROPRINT 5000?
A
andrewsmikeAug 28, 2025
Error #0002 indicates that the air pressure is too low. This could be due to a disconnected pressure hose, low pressure adjustment, or low supply pipe pressure.
C
Christopher JimenezAug 27, 2025
What does error #0001 mean on MHM SYNCHROPRINT 5000?
L
Laura HallAug 27, 2025
Error #0001 indicates that the emergency stop circuit is interrupted. This could be because the emergency stop button has been pressed, a safety barrier has been opened, “Control ON/OFF” is off, or the reset button has not been pressed.
M
Mrs. Sandra HerreraAug 27, 2025
What to do if unlock screens does not work on MHM SYNCHROPRINT 5000?
J
James GreerAug 27, 2025
If the unlock screens aren't working, consider the following:
* The low pressure adjustment might be incorrect. Check the adjustment of the precision pressure regulator.
* The valve might not be actuated. Check the wiring between the station PCB, Bus- PCB, and the squeegee valve.
J
Joshua PetersAug 25, 2025
What to do if squeegee does not toggle at squeegee carriage movement in MHM Industrial Equipment?
S
Shane ButlerAug 26, 2025
If the squeegee doesn't toggle during squeegee carriage movement, consider the following:
* The squeegee pressure might be too low. Try adjusting the pressure control at the print station.
* There might be no air pressure at the print station. Check if the lower pressure stop cock is active or if a tube has snapped off.
* The valve might not be actuated. Check the wiring between the station PCB and the squeegee valve.
S
Shirley MiddletonAug 25, 2025
What to do if safety level cannot be adjusted on MHM Industrial Equipment?
J
Joshua PeckAug 25, 2025
If the safety level cannot be adjusted, it might be due to these reasons:
* The safety key is not connected to the Distribution- PCB. Check the wiring from the safety key to the Distribution-PCB.
* There is wrong wiring of the safety key at the panel housing. Take the terminal out of the housing and check the wiring of the safety key.