EasyManuals Logo

Midtronics CTU-6000 User Manual

Midtronics CTU-6000
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
34
Adding jar model information to the database
To add new jar models and conductance reference values to the database, use BATTERY MANAGER
in the Main Menu. The BATTERY MANAGER available in BATTERY SETUP allows you to change
a reference value only for a particular data le. It does not save the change as a selection for new
test setups. You can also edit a model name or add a new model using BATTERY MANAGER in the
Main Menu.
Changing a reference value
1. Press the ARROW keys to highlight the BATTERY MANAGER in the Main Menu, and press
ENTER.
2. Press the
ARROW keys to select a manufacturer, and press ENTER.
3. To change a reference value for a model in the database, press the
ARROW keys to select
the model name, and press
ENTER.
4. In the EDIT MFGR screen, press the
DOWN ARROW to select REFERENCE, and press
ENTER.
NOTE: If you change the model name and save it, the new name overwrites the original
model name in the database.
5. Press the
ARROW keys (or use the numeric keypad) to select a new reference value, and
press
ENTER.
6. To save, press the
DOWN ARROW to select SAVE AND CONTINUE, and press ENTER.
Adding a jar model
1. Press the ARROW keys to highlight the BATTERY MANAGER in the Main Menu, and press
ENTER.
2. Press the
ARROW keys to select a manufacturer, and press ENTER.
3. Press the
ARROW keys to select one of the numbered USER DEFINED names, and press
ENTER.
4. In the MODEL ID screen, your USER DEFINED selection is highlighted. Press
ENTER to
change the name.
5. The cursor blinks to the right of the last space or character in the name. Display the charac-
ter, symbol, or number you want by rapidly pressing its key as many times as needed. If you
pause, the cursor moves to the right. To backspace one character, press the
BACK key. To
enter a space between characters, press the
key twice. Press ENTER when nished.
6. In the MODEL ID screen, press the
DOWN ARROW to select REFERENCE, and press
ENTER.
7. Press the
ARROW keys (or use the numeric keypad) to select a new reference value.
8. To save, press the
DOWN ARROW to select SAVE AND CONTINUE and press ENTER.
Chapter 5: Selecting test parameters Celltron ULTRA

Table of Contents