Technical Information
55
CVA 610/CVA 615 Coffee Systems
Figure 5-22: Brew Unit Removal for Cleaning
3. Pull outward to remove the brew unit (Figure 5-22, Item 2).
4. Clean the brew unit thoroughly under warm running water without
detergent.
5. Rub away coffee residues from the steel filters with a sponge.
6. Dry the funnel to prevent ground coffee from sticking.
7. After cleaning, press "PRESS".
8. Remove the waste container (if it was re-installed).
9. Push the brew unit straight into the track, without pressing “PRESS”, until it clicks
into place. See Figure 5-23.
Figure 5-23: Brew Unit Installation
5.30 Brew Unit Filter Cleaning
1. Wipe away coffee residues from the steel filter in the funnel of the brew unit with
a sponge.
2. The filters can be removed for thorough cleaning.
3. Remove the brew unit.
4. Insert a 5mm Allen key in the connection socket in the brew unit. Turn
counterclockwise while supporting the chrome filter from underneath. Remove
the filter by lifting it from the brew unit.
5. Access the second filter by placing a long Philips screwdriver through the center
of the funnel and removing the screw in the center of the filter.
6. Manually move the brew unit into the “brew” position.
7. Turn the brew unit upside down; the filter will fall out.
8. Clean both sides of the filter with hot water and let it dry.
9. Re-install the second filter back into position.
10. Manually move the brew unit to the “home” position.
11. Re-install the Philips screw in the center of the filter.
12. Re-install the first filter in the brew unit and secure by turning the Allen key
clockwise.