63
CVA 610/CVA 615 Coffee Systems
Figure 5-35: Screws Securing the Brew Unit Drive Cover (CVA 610)
5.38.2 CVA 615
1. Disconnect the power. Allow the appliance to cool.
2. Remove the brew unit from the appliance; see Section 5.26.
3. Remove the waste container from the appliance.
4. Remove the beans container and beans container guide; see Sections 5.42 and
5.43.
5. Remove the lid; see Section 5.1.
6. Remove the interference suppression capacitor; see Section 5.2.
7. Remove the rear panel; see Section 5.6.
Important!
Before unplugging any connections, label the plugs and connectors to ensure that
the wiring is returned to the correct locations during reassembly.
8. Disconnect L1 and N from the door switch to the interference suppression
capacitor.
9. Disconnect the green ground wires from the cord socket/terminal block.
10. Disconnect the following connections from the power electronic:
JP2
JP12
JP4
11. Disconnect the following connections from the CPU electronic:
JP34