EasyManua.ls Logo

Miele cva 610 - Table 6-2: Service Mode Functions

Miele cva 610
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
80
CVA 610/CVA 615 Coffee Systems
6. Brew unit present switch
7. Water tank level switch
8. Flow meter pulse (not always displayed)
A. Drip tray filled (water system fault)
4. Turn the selector switch to the desired function (see Table 6-2).
5. Release the SMALL COFFEE and HOT WATER buttons.
6. Press the applicable button to activate the function.
Selector Switch
Position
Button Function
Lock
Large Coffee
Displays water temperature (in °C) for
water heater and steam heater.
Med Coffee
Displays firmware version.
Small Coffee
(not used)
Hot Water
(not used)
Rinse
(not used)
Water pump on.
Program Mode
Steam solenoid on.
Hot-water valve on.
Displays, "5."
Displays, "4."
Button test “1” displayed.
Button test “2” displayed.
Light
Button test “3” displayed.
Button test “5” displayed.
Button test “4” displayed.
Drive motor on until brew position switch is
contacted.
On w/ Light
Drive motor on (reverse direction) until
home switch is contacted.
Grinder on.
(not used)
Dispenser solenoid on.
Hot water/coffee side heater element on.
ON
Hot water/coffee upper heater element on.
Steam heater element on.
Front lights (CVA 615 only)
(not used)
Table 6-2: Service Mode Functions