EasyManua.ls Logo

Miele cva 610 - Closing Water Path Connections

Miele cva 610
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
78
CVA 610/CVA 615 Coffee Systems
Figure 5-54: Water System Connections with Clip
5.54 Closing Water Path Connections
1. Check the seals for damage and replace as necessary.
2. Install the seals on the hose.
3. Insert the hose in the connector.
4. Install the retaining clip behind the pressed-on ring (Figure 5-54, Item 3).
5. As a check, pull on the hose. It should not be possible to pull the hose out of the
connector.
Note:
The pressed-on rings cannot be replaced as a separate component.
Should replacement be necessary, the hose (as an assembly) must be
replaced.
5.55 Flow Meter Removal
5.55.1 CVA 610
1. Remove the lid; see Section 5.1.
2. Disconnect the flow meter electrical connection.
3. Remove the hoses from the flow meter.
4. Release the flow meter from its plastic mounting bracket.
5.55.2 CVA 615
1. Remove the lid; see Section 5.1.
2. Disconnect the flow meter electrical connection.
3. Remove the hoses from the flow meter.
4. Release the flow meter from its plastic mounting bracket.

Table of Contents

Other manuals for Miele cva 610

Related product manuals