Technical Information
79
CVA 610/CVA 615 Coffee Systems
6.0 Fault Diagnosis
6.1 Programming Mode
The programming mode is available for access by the customer. The programming
mode offers various functions and/or features to configure.
To access the programming mode, simply turn the selector knob to the “Program
Mode” position.
Function Options
Language
German, Dutch, Portuguese, Spanish, English,
Italian, French
Rinsing
On, Off
Water Hardness
Hardness Levels 1 to 4
Temperature Long Coffee
Minimum, Low, Medium, High, Maximum
Temperature Coffee
Minimum, Low, Medium, High, Maximum
Temperature Short (Espresso) Coffee
Minimum, Low, Medium, High, Maximum
Pre-Brewing
On, Off
Pre-Grinding
Off, On
Program Hot Water
Off, On
Total Coffee
Number of coffee servings
Descaling
Automatic descaling program
Standby Timer
To put appliance in standby mode; selectable
in 15-minute intervals
Table 6-1: Programming Mode
6.2 Service Mode
The service mode is used to check the status of various input switches and to
operate components in the appliance. The service mode is designed for use by
qualified service personnel.
Accessing service mode:
1. Switch off the appliance.
2. Ensure that the front door is locked.
3. Press and hold the SMALL COFFEE and HOT WATER buttons together. The
display will read as follows (example):
567
2 128
The display indicates the switches that are currently actuated.
1. Brewing position switch (brew unit drives)
2. Home position switch (brew unit drives)
3. Dispenser switch
4. Steam valve switch
5. Waste container present switch
Electronic
Version