Technical Information
56
CVA 610/CVA 615 Coffee Systems
5.31 Brew Unit Degreasing via the Rinse Cycle
Note:
The natural oil found in coffee can cause the brew unit to clog. The message
“Rinsing Cycle” will flash in the message window after 500 cups to remind you to
clean the brew unit using cleaning tablets. These specialty cleaning tablets can be
purchased from Miele.
1. Remove the waste container.
2. Take out the brew unit and put the cleaning tablet in the brew unit funnel. See
Figure 5-24.
Figure 5-24: Placing Cleaning Tablet into Brew Unit Funnel
3. Return the brew unit and waste container to the appliance and close the door.
4. Place a 3-cup (25-ounce) container under the coffee dispensers.
5. Press the rinse/pre-warm button. (The appliance must be pre-heated and ready
to use, or the button will not respond.)
6. The display will read:
7. Press to select “Rinsing cycle” with the asterisk.
8. Press ENTER. The display will read:
9. A small amount of water will flow out of the coffee dispensers. After a pause,
more water will flow out. This process will run 4 times, dispensing 2 cups (17
ounces) of hot water. The whole procedure takes about 5 minutes.
10. At the end of the cleaning cycle, the display will read:
11. The brew unit is now clean and ready to use.