OM-272476 Page 27
SECTION 8 SMAW/CAC-A OPERATION
8-1. Typical Connection For SMAW And CAC-A Process
! Turn off power before making con-
nections.
1 Electrode Holder
(Carbon Arc)
For CAC-A process connect carbon arc
cutting torch to positive weld output termi-
nal.
2 Electrode Holder
3 Positive (+) Weld Output Terminal
4 Remote 14 Receptacle
Connect desired remote control to remote
14 receptacle as required.
5 Compressed Air LIne
6 Negative (−) Weld Output Terminal
7 Workpiece
1
2
7
6
3
4
5
269 326-A