3-28
8
Press the key.
The scale compensation display appears.
(The right figure shows the 4-point detection display
as an example.)
9
Make setting with the jog key or
.
Press the key to change the display to
the next scale compensation setting.
If [DIST.REVI.] is set to [OFF], the display for scale
compensation setting will not appear.
If [MARK DETECT] its set to [2ptA], the display for inputting the B length will not appear.
If [MARK DETECT] is set to [1pt], the scale compensation setting display will not appear
but the origin point will be displayed.
10
Press the key after
completing the settings.
The plotter will start detecting the registration
marks according to the settings of [MARK
DETECT].
See "Setting the Number of Registration Mark
Detection" P. 3 -1 9 for the number of
registration marks.
In case the plotter cannot detect any registration marks, it displays “Error 36 in the
registration mark detection” on the display. Set the sheet again.
11
Set the origin.
The display will show the available cutting area
and then return to local mode.
SEARCH START POS
A(1-2)=***.*
ENTER/HOLD
A(1-2)=***.*
B(1-3)=***.*
ENTER/HOLD
B(1-3)=***.*
* *MARK DETECT * *
ENTER/HOLD
** ORIGIN **
A=**** B=****
CUT1 20 050 0 . 30