3-29
Cut Out Data with Registration Mark
3
Useful Function
Detecting procedure ( [DIST.REVI.] Setting value is “BEFOR”)
1
Follow steps 1 to 3 of "Detecting procedure ( [DIST.REVI.] Setting
value is “BEFOR”)" ( P.3-27)
2
Press the key.
The plotter will start detecting the registration
marks according to the settings of [MARK
DETECT].
See "Setting the Number of Registration Mark Detection" P.3-19 for the number of
registration marks.
In case the plotter cannot detect any registration marks, it displays “Error 36 in the
registration mark detection” on the display. Set the sheet again.
3
After the detection of the registration
marks, the scale compensation display
appears.
The right figure shows the 4-point detection display as an example.
If there is a difference between the actually measured value and the detected length,
make setting with the jog key or .
Press the key to change the display to the next scale compensation setting.
If [DIST.REVI.] is set to [OFF], the display for scale compensation setting will not appear.
If [MARK DETECT] is set to [2ptA], the display for inputting the B length will not appear.
If [MARK DETECT] is set to [1pt], the scale compensation setting display will not appear
but the origin point will be displayed.
4
Press the key after
completing the settings.
Set the origin.
The display will show the available cutting area
and then return to local mode.
* *MARK DETECT * *
ENTER/HOLD
A(1-2)=***.*
ENTER/HOLD
** ORIGIN **
A=**** B=****
CUT1 20 050 0 . 30
ENTER/HOLD