Cut Out Data with Registration Mark
3-38
7
Press the key.
The offset value of the cutter and the mark sensor
can be adjusted.
Set the sheet on which the register mark is printed.
8
Enter the corrected value (mm) by
pressing the for the A
direction, or the for the B
direction.
If misaligned by +0.2 mm, enter "-0.2".
9
Press the key.
The plotter will return to the local mode after
registering the compensation value.
The setting values are kept in memory even when the power is turned off.
The sensor offset value selected by this operation is not initialized by SETUP RESET
operation.
A=0 . 0 B=0 . 0
ENTER/HOLD
A direction
B direction
Misaligned by +0.2 mm from
the center line of the register
mark ( ) in the A and the
B direction.
A= - 0 . 2 B= - 0 . 2
CUT1 20 050 0 . 30