EasyManua.ls Logo

MIMAKI CJV150-130 - 2.3.12 Pen Encoder PCB Assy.

MIMAKI CJV150-130
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-27
2
2
2
2
2
Chapter 2 Basic Operation
Set the Cut Conditions
Set the condition to cut or to plot with a pen.
Setting contents of cutting condition (CUT1 to 7):
Cut speed (SPEED)/ cut pressure (PRESS)/ OFFSET
value/ Half cut
Setting contents of plotting condition (PEN):
Plotting speed (SPEED)/ pen pressure (PRESS)
1
Press the key in LOCAL to display
the “TOOL” menu.
2
Press the (TOOL).
3
Press to select a tool condition to
be used, and press the key.
4
Press to move the cursor to cutting
speed, and press the key.
5
Press to set the cutting speed,
and press the key.
Set the moving speed of the tool for cutting or pen
plotting.
Setting values : 1 to 10cm/s
(settable by 1cm/s step)
15 to 30cm/s
(settable by 5cm/s step)
6
Press to move the cursor to cutting
pressure, and press the key.
7
Press to set the cutting pressure,
and press the key.
Set the pressure that the tool presses the sheet
for cutting or pen plotting.
Setting values : 10 to 20g (settable by 2g step)
25 to 100g (settable by 5g step)
110 to 450g (settable by 10g
step)
8
Press to move the cursor to OFFSET,
and press the key.
9
Press to set the offset value, and
press the key.
When you set the cutting condition (CUT1 to 7),
set the distance between the center of the cutter
holder and the blade tip.
Setting values : 0 to 250 (0.00 to 2.50mm)
(settable by 0.05mm step)
10
Press to move the cursor to half cut,
and press the key.
11
Press to set ON/OFF, and press
the key.
When you perform half cut, select ON and
proceed to the Step 11.
When you do not want to set AUTO CUT, select
"OFF" and proceed to Step 17.
12
Press to move the cursor to pressure
setting of left part (not to be cut), and press
the key.
13
Press to set pressure, and press
the key.
Set the pressure of the left part (not to be cut)
when performing half cut.
Setting values : 0 to 450g (settable by 5g step)
14
Press to move the cursor to the
setting of length to be left, and press the
key.
15
Press to move the cursor to the
setting of length to be left, and press the
key.
Set the length to be left not to be cut when
performing half cut.
Setting values : 0.1 to 5mm
(settable by 0.1mm step)
16
Press to move the cursor to the
setting of cut length, and press the
key.
17
Press to set the cut length, and
press the key.
Set the length to be cut when performing half cut.
Setting values : 5 to 150 mm
(5 to 20mm: 1mm step, 20 to
150mm: 5mm step)
18
Press the key to register the
set contents.
Return to the local.
When the cutting (plotting) pressure setting is
completed, proceed to the setting of the
OFFSET value. When you set the plotting
condition (PEN), you cannot set the OFFSET
value and half cut. Proceed to the Step 16.
The maximum pressure at selecting PEN is 150g.
Cutter
holder
OFFSET
Blade
Nothing is displayed on the LCD if "0" is specified.
The set value is retained even when the power is
turned “OFF”.

Table of Contents

Other manuals for MIMAKI CJV150-130

Related product manuals