Page #136 background imageLoading...
Page #136 background image
4-14
Setting of skew check
Resetting the Setting of Register Mark Detection
In case the cutter unit detects a medium that has no printing of register marks and displays [SEARCH START
POS.], set the register mark detection to "OFF".
Then, the register mark detection is disabled.
Set Value Description
0 to 99 mm
This will set the allowable value of sheet declination when copying continuously.
When copying continuously for roll sheet, the printing position may be misaligned gradually because
of the sheet declination etc. In such a case, the operation can be continued by detecting register
marks again with the following procedures:
If the coordinate value of B axis of the Register mark 1 is misaligned exceeding the setting value,
cutting operation suspends.
When pressing the key, the device enters the register mark detection waiting mode.
To restart the register mark detection, move the light spot of the light pointer to the position
described in the figure below with the jog key and press the
key.
At this time, do not correct the medium by raising the clamp lever. The operation cannot be
continued.
If check is not performed, set “0”.
Follow Steps 1 to 5 in
"Setting Register Mark
Detection".
Press to
select "OFF".
Press the key.
Press the
several times.
Position of starting
register mark detection
Reference
mark 1
MARK TYPE 1 MARK TYPE 2
Reference
mark 2

Table of Contents

Other manuals for MIMAKI JV5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV5 Series and is the answer not in the manual?

MIMAKI JV5 Series Specifications

General IconGeneral
BrandMIMAKI
ModelJV5 Series
CategoryPrinter
LanguageEnglish

Related product manuals