MIMAKI UJF-3042 MkII Series - Setting of LT Mode; Setting of Scan Speed; Setting of SUCTION WIPER

MIMAKI UJF-3042 MkII Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-15
Chapter 3 Setup
3
2
2
2
Setting of LT mode
1
Press the (MENU) key in the local
mode.
2
Press to select "Setting", then
press the key.
The setting menu is displayed.
3
Press the
(>>)
.
4
Press to select “LT mode” , and
press the key.
5
Press to select a set value, and
press the key.
Set value :ON / OFF
6
Press the key several times to
end the setting.
Setting of SUCTION WIPER
Set the head that executes WIPING AFTER PRINT and
the execution interval.
1
Press the (MENU) key in the local
mode.
2
Press to select "Setting", then
press the key.
The setting menu is displayed.
3
Press the
(>>)
.
4
Press to select “SUCTION
WIPER” , and press the key.
5
Press the key.
WIPING AFTER PRINT menu is displayed.
6
Press the key.
SELECT HEAD menu is displayed.
7
Press to select the heads for
WIPING AFTER PRINT, then press
(
)
.
Only heads with check boxes selected will be
suction-wiped after printing.
Head 4 (Head 3 with 3042MkII) is always
selected.
8
Press the key.
9
Press to select “EXEC
INTERVAL” , and press the key.
10
Press the key.
EXEC INTERVAL setting menu is displayed.
11
Press to select the set value, and
press the key.
Set value: FILE/WORK CHANGE
When set value is set to "FILE", proceed to Step
12. Otherwise, proceed to Step 14.
12
Press to select “Interval” , and
press the key.
13
Press to change interval , and
press the key.
Set value: 1 to 5
14
Press the key several times to
end the setting.
Setting of Scan Speed
1
Press the (MENU) key in the local
mode.
2
Press to select "Setting", then
press the key.
The setting menu is displayed.
3
Press the
(>>)
.
4
Press to select “Scan Speed” ,
and press the key.
5
Press to select a set value, and
press the key.
Set value : STANDARD / LOW
6
Press the key several times to
end the setting.
Since UV light intensity adjustment is performed,
check the print performance (stickiness, odor etc.)
before using the LT mode.
Effective condition
Ink type Resolution Pass Media
LUS120 600 x 600 8 pass UV PET
When the set value is set to "FILE", wiping after
print will only be performed at set intervals.
When the set value is set to "WORK CHANGE",
wiping after print will only be performed at the time
of work change.