10. SPM | 10.4 - System data | 172
SPM address Data type R/W Function
X64 BOOL R/W Read/write marker bit1
X65 BOOL R/W Read/write marker bit2
X66 BOOL R/W Read/write marker bit3
X72 BOOL R/W Switch D11 to net weight.
X112 BOOL W Zero device.
X113 BOOL W Tare device
X114 BOOL W Reset the tare of the device
X115 BOOL W Start the test mode
X116 BOOL W Finish the test mode
X117 BOOL W Reset the power fail signal
X118 BOOL W Set fixed tare weight D31 as tare
X119 BOOL W Store the current gross weight in the preset tare memory
(D31)
X120 BOOL W Start printing
X121 BOOL W Reset error B19 = 0.
B16 SINT R Exponent
Number of decimal places
Example: 1.23 is displayed
Exponent: 2
B17 SINT R Weight unit 2 = g, 3 = kg, 4 = t, 5 = lb
B18 SINT R Verification scale interval (for multi-interval/multi-range
= d1 or e1)
B19 BYTE R Last weighing point error, see ChapterError numbers @
"LAST_ERROR".
B20 BYTE R Higher byte of product code (0x52)
B21 BYTE R Lower byte of product code (0x15)
B22 BYTE R Major part of version number (1.0)
B23 BYTE R Minor part of version number (1.0)