EasyManuals Logo

Minolta DYNAX 7 Repair Guide

Minolta DYNAX 7
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
32 (2181)
REPAIR GUIDE
Related adjustment and required setting items
When each adjustment or setting is operated, be sure to follow the related adjustment and setting items
listed blow.
Number : Related adjustment items. Adjust and set in order of the number.
× : Related adjustment items. However, these items mean not to adjust the adjustment order is
different (the adjustment should be completed).
None : Unrelated adjustment and setting items (possible to adjust and set solely).
Related
adjustment
Adjustment
Viewfinder Back
SPC Position
Manual Set SS
PI-PR
Aperture Preset
AF Area
PITCH,YAW
EZ
CCD
Vsub
CCD Aori and Center
ACT DRV FREG
SERVO GAIN
GYRO
AE
GAIN
DEFECT PIXEL
WB
SHAKE GAIN
Viewfinder Back ×
SPC Position 1
Manual Set SS 12
PI-PR
Aperture Preset
AF Area (1) 2
PITCH, YAW (1) 2
EZ × ×
CCD
Vsub 12
CCD Aori and Center 123
ACT DRV FREG 1 2 3
SERVO GAIN × 1 2
GYRO × × 1
AE ×
GAIN × ×× 123
DEFECT PIXEL ×1
WB × × × ×
SHAKE GAIN ×××× ××

Table of Contents

Other manuals for Minolta DYNAX 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minolta DYNAX 7 and is the answer not in the manual?

Minolta DYNAX 7 Specifications

General IconGeneral
Camera TypeSLR
Film Format35mm
Flash Sync Speed1/200 sec
Sensor TypeN/A (Film Camera)
Sensor SizeN/A (Film Camera)
Effective PixelsN/A (Film Camera)
Lens MountMinolta A mount
Shutter Speed1/8000 to 30 sec, Bulb
ISO RangeISO 6 to 6400
ISO SensitivityISO 6 to 6400
ViewfinderPentaprism
Storage MediaN/A (Film Camera)

Related product manuals