REPAIR GUIDE
Adjustment of the gyro for camera shaking (GYRO)
Required equipment
PC with preinstalled the 2181 adjustment program
CF card for Adjustment
USB-2 (USB cable)
AC Adapter AC-11
Preparation of the adjustment
Set camera to adjustment mode.
Refer to Starting up the 2181 adjustment program (in the adjustment mode) in P. 49.
Procedure of the adjustment
1. Click "GYRO " of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.
Adjustment of the frequency for camera shaking (ACT DRV FREQ)
Required equipment
PC with preinstalled the 2181 adjustment program
CF card for Adjustment
USB-2 (USB cable)
AC Adapter AC-11
Preparation of the adjustment
Set camera to adjustment mode.
Refer to Starting up the 2181 adjustment program (in the adjustment mode) in P. 49.
Procedure of the adjustment
1. Click "ACT DRV FREQ" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.
Adjustment of the servo for camera shaking (SERVO)
Required equipment
PC with preinstalled the 2181 adjustment program
CF card for Adjustment
USB-2 (USB cable)
AC-11
Preparation of the adjustment
Set camera to adjustment mode.
Refer to Starting up the 2181 adjustment program (in the adjustment mode) in P. 49.
Procedure of the adjustment
1. Click "SERVO" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.