3 ANALOG OUTPUT MODULE REPLACEMENT
3 - 57
3.8.4 Buffer memory address comparison
Sequence program change is required as the assignment of buffer memory differs.
For details of the buffer memories and sequence program, refer to the Digital-Analog Converter Module
User's Manual.
A68DAI(-S1) Q68DAIN
Address
(decimal)
Name Read/write
Address
(decimal)
Name Read/write
0 D/A conversion enable/disable channel
R/W
0 D/A conversion enable/disable
R/W
1 CH1 Digital value 1 CH1 Digital value
2 CH2 Digital value 2 CH2 Digital value
3 CH3 Digital value 3 CH3 Digital value
4 CH4 Digital value 4 CH4 Digital value
5 CH5 Digital value 5 CH5 Digital value
6 CH6 Digital value 6 CH6 Digital value
7 CH7 Digital value 7 CH7 Digital value
8 CH8 Digital value 8 CH8 Digital value
9 Resolution of digital value 9
System area (Not used) -
10 CH1 Setting value check code
R
10
11 CH2 Setting value check code 11 CH1 Setting value check code
R
12 CH3 Setting value check code 12 CH2 Setting value check code
13 CH4 Setting value check code 13 CH3 Setting value check code
14 CH5 Setting value check code 14 CH4 Setting value check code
15 CH6 Setting value check code 15 CH5 Setting value check code
16 CH7 Setting value check code 16 CH6 Setting value check code
17 CH8 Setting value check code 17 CH7 Setting value check code
18 CH8 Setting value check code
19 Error code
20 Setting range (CH1 to CH4)
21 Setting range (CH5 to CH8)
22
Offset/gain setting mode
Offset specification
R/W
23
Offset/gain setting mode
Gain specification
24 Offset/gain adjusted value specification
25
System area (Not used) -
to
157
158
Mode switching setting R/W
159
160
System area (Not used) -
to
201
202 CH1 Industrial shipment settings offset value
R/W
203 CH1 Industrial shipment settings gain value
204 CH2 Industrial shipment settings offset value
205 CH2 Industrial shipment settings gain value
206 CH3 Industrial shipment settings offset value
207 CH3 Industrial shipment settings gain value
208 CH4 Industrial shipment settings offset value