6  HIGH-SPEED COUNTER MODULE REPLACEMENT
6 - 11
6.3.2 Function comparison
: With functions, -: Without functions
Item Description AD61S1 QD62-H02 Precautions for replacement
Preset function
Changes the counter present value to a 
specified value.
Disable function Terminates counting.
Ring counter function
Repeatedly executes counting between 
user's setting values.
On QD62-H02, the setting is 
carried out using intelligent 
function module switch setting.
Linear counter function
If the count exceeds the range, this function 
detects an overflow.
-
Coincidence output function
Outputs signals when user and the present 
values are matched.
No.1 and No.2 coincidence 
output points can be set for each 
channel.
Coincidence detection interrupt 
function
Generates an interrupt signal to the 
programmable controller CPU when 
coincidence is detected.
-
Latch counter function
Latches the present value at the time a 
signal is input.
-
Sampling counter function
Counts the pulses that are input during the 
sampling time set.
-
Periodic pulse counter function
The function allows storing the present 
value in the periodic pulse count present 
value and the previous value in the periodic 
pulse count previous value for each period 
time set.
-