7 POSITIONING MODULE REPLACEMENT
7 - 24
7.5.2 Function comparison
(1) Deleted function from AD75M1/AD75M2/AD75M3
When using the following function on AD75M -S3, change the program.
Deleted functions Precautions for replacement
Creep speed out of range error
(error code: 208)
With QD75M, there is no the error code of the left column.
Fast machine OPR With the Q75M, there is no possible function for replacement.
Special start (stop) Execute it separately for the start two times.
Indirect designation
In the QD75M, the start block area on the buffer memory is expanded to five blocks (0 to 4). Each
start block can be directly designated with positioning start No. (7000 to 7004).
Block transfer With the AD75M, this interface is used to set positioning data Nos. 101 to 600 that do not exist on
the buffer memory. Since all positioning data can be set in the buffer memory with the QD75M, this
function is deleted.
Positioning data I/F
Start history during errors
The contents are the same as the start history.
Therefore, the QD75M stores only the start history.
System monitor data
(Module name, OS type, OS version)
These data were deleted because they can be displayed in system monitor "Module's detailed
information" of GX Developer.
(Refer to GX Developer Operating Manual.)