4 TEMPERATURE INPUT MODULE REPLACEMENT
4 - 17
*1 If a value entered from the thermocouple is outside the measured temperature range given in the table, it is handled as the
maximum/minimum value of the measured temperature range.
*2 The accuracy only in the temperature ranges of Class 1 to 3 (shaded areas) in JIS C1602-1995 apply.
Also, a warm-up (power distribution) period of 30 minutes is required to satisfy with the accuracy.
*3 A temperature can be measured; however, the accuracy is not guaranteed.
Q68TD-G-H02, Q68TD-G-H01
Applicable
thermocouple
type
Measured temperature
range
*1
Conversion accuracy
(at operating ambient
temperature 25±5°C)
Temperature characteristics
(per operating ambient
temperature variation of 1°C)
Maximum temperature
error at ambient
temperature of 55°C
B
0 to 600°C
------
*3
------
*3
------
*3
600 to 800°C
*2
±3.0°C
±0.4°C
±13.0°C
800 to 1700°C
*2
±2.5°C ±12.5°C
1700 to 1820°C
------
*3
------
*3
------
*3
R
-50 to 0°C
------
*3
------
*3
------
*3
0 to 300°C
*2
±2.5°C ±0.4°C ±12.5°C
300 to 1600°C
*2
±2.0°C ±0.3°C ±9.5°C
1600 to 1760°C
------
*3
------
*3
------
*3
S
-50 to 0°C
------
*3
------
*3
------
*3
0 to 300°C
*2
±2.5°C ±0.4°C ±12.5°C
300 to 1600°C
*2
±2.0°C ±0.3°C ±9.5°C
1600 to 1760°C
------
*3
------
*3
------
*3
K
-270 to -200°C
------
*3
------
*3
------
*3
-200 to 0°C
*2
Larger value of ±0.5°C or ±0.5%
of measured temperature
Larger value of ±0.06°C or ±0.2%
of measured temperature
±11.0°C
0 to 1200°C
*2
Larger value of ±0.5°C or ±0.25%
of measured temperature
Larger value of ±0.06°C or
±0.02% of measured temperature
±9.0°C
1200 to 1370°C
------
*3
------
*3
------
*3
E
-270 to -200°C
------
*3
------
*3
------
*3
-200 to 0°C
*2
Larger value of ±0.5°C or
±0.5% of measured temperature
Larger value of ±0.06°C or
±0.15% of measured temperature
±8.5°C
0 to 900°C
*2
Larger value of ±0.5°C or
±0.25% of measured temperature
Larger value of ±0.06°C or
±0.02% of measured temperature
±6.75°C
900 to 1000°C
------
*3
------
*3
------
*3
J
-210 to -40°C
------
*3
------
*3
------
*3
-40 to 750°C
*2
Larger value of ±0.5°C or
±0.25% of measured temperature
Larger value of ±0.06°C or
±0.02% of measured temperature
±5.625°C
750 to 1200°C
------
*3
------
*3
------
*3
T
-270 to -200°C
------
*3
------
*3
------
*3
-200 to 0°C
*2
Larger value of ±0.5°C or
±0.5% of measured temperature
Larger value of ±0.06°C or
±0.1% of measured temperature
±6.0°C
0 to 350°C
*2
Larger value of ±0.5°C or
±0.25% of measured temperature
Larger value of ±0.06°C or
±0.02% of measured temperature
±2.625°C
350 to 400°C
------
*3
------
*3
------
*3
N
-270 to -200°C
------
*3
------
*3
------
*3
-200 to 0°C
*2
Larger value of ±0.5°C or
±0.5% of measured temperature
Larger value of ±0.06°C or
±0.2% of measured temperature
±11.0°C
0 to 1250°C
*2
Larger value of ±0.5°C or
±0.25% of measured temperature
Larger value of ±0.06°C or
±0.02% of measured temperature
±9.375°C
1250 to 1300°C
------
*3
------
*3
------
*3