4 TEMPERATURE INPUT MODULE REPLACEMENT
4 - 45
Item A68RD3N
Cables between module and
RTD
Make sure that the conductor resistance value between the Pt100 and A68RD3N is 10 or less per
conductor.
All channels become the same specifications.
Internal current consumption
(5VDC)
0.94A
Weight 0.43kg
Pt100
1)
2)
3)
Conductor
A68RD3N
A
B
b
SLD
Lay wiring so that the following conditions are met.
10 or less
1) Conductor resistance value 10 ( )
2) Conductor resistance value 10 ( )
3) Conductor resistance value 10 ( )

Table of Contents