7 POSITIONING MODULE REPLACEMENT
7 - 26
Command in-position function
The command in-position width is expanded.
•AD75M: 1 to 32767000
• QD75M: 1 to 2147483647
Positioning start No. 7004 to 7010 (block start designation) and 8000 to 8049 (indirect designation) are deleted.
Block start data
With QD75M, number of blocks has been change to 5 (7000 to 7004).
(With the AD75M, this data is called "Positioning start information".)
Start history
The configuration of start information and start No. is changed so that the start No. can be directly
checked.
Detailed parameters
“ Software stroke limit valid/
invalid setting”
AD75M QD75M
0
(Factory setting)
Software stroke limits invalid for
manual operation
Software stroke limits valid for
manual operation
1
Software stroke limits valid for
manual operation
Software stroke limits invalid for
manual operation
Changed functions Change description