Chapter 5 Data Used for Positioning Control
Control
Positioning parameter
HPR control
Major positioning control Manual control
Expansion
control
Related sub function
Position control
1 to 4 axis speed control
Speed-position or position-speed control
Other control
Manual pulse generator operation
Inching operation
JOG operation
Speed-torque control
1-axis linear control
2/3/4-axis linear inter
p
olation control
1-axis fixed-feed control
2/3/4-axis fixed-feed control
2-axis circular interpolation control
Current value changing
JUMP instruction, NOP instruction,
LOOP to LEND
Detailed parameters 2
[Pr.25] Acceleration time 1
– –
13.7.6
[Pr.26] Acceleration time 2
– –
[Pr.27]
Acceleration time 3
– –
[Pr.28] Deceleration time 1
– –
[Pr.29]
Deceleration time 2
– –
[Pr.30] Deceleration time 3
– –
[Pr.31] JOG speed limit value
– 13.4.1
[Pr.32] JOG operation acceleration time selection – – – – – – – –
– –
[Pr.33] JOG operation deceleration time selection – – – – – – – –
– –
[Pr.34]
Acceleration/deceleration process selection
– –
13.7. 6
[Pr.35] S-curve ratio
– –
[Pr.36]
Rapid stop deceleration time
– –
[Pr.37] Stop group 1 rapid stop selection
– –
– –
[Pr.38] Stop group 2 rapid stop selection
– –
– –
[Pr.39]
Stop group 3 rapid stop selection
– –
– –
[Pr.40] Positioning complete signal output time
– –
[Pr.41]
Allowable circular interpolation error width
– – – –
[Pr.42] External command function selection
– –
13.5.1
13.7.2
[Pr.83]
Speed control 10 x multiplier setting for
degree axis
13.7.10
[Pr.84]
Restart allowable range when servo OFF
to ON
5.2.4
[Pr.89]
Manual pulse generator/Incremental
synchronous encoder input type selection
– – – – – –
– –
5.2.4
[Pr.90]
Operation setting for speed-torque control
mode
– – – – – – – –
12.1
[Pr.95]
External command signal selection
– –
: Alwa ys set
: Set as required ("–" when not required)
: Setting not required (If the value is the default value or within the setting range, there is no problem.)
Checking the positioning parameters
[Pr.1] to [Pr.90], [Pr.95] are checked with the following timing.
When the "PLC READY signal [Y0]" output from the PLC CPU to the Simple
Motion module changes from OFF to ON.
When the positioning test of GX Works2 is executed.
REMARK
"High-level positioning control" is carried out in combination with the "major
positioning control".
Refer to the "major positioning control" parameter settings for details on the
parameters required for "high-level positioning control".