9 - 56 
Chapter 9    Major Positioning Control 
 
9.2.9 4-axis fixed-feed control (interpolation) 
In "4-axis fixed-feed control" ("[Da.2] Control method" = fixed-feed 4), four motors are 
used to carry out fixed-feed control in a linear path while carrying out interpolation for 
the axis directions set in each axis.   
In fixed-feed control, any remainder of below control accuracy is rounded down to 
convert the movement amount designated in the positioning data into the command 
value to servo amplifier. 
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.) 
 
 Operation chart 
 
In incremental system 4-axis fixed-feed control, the addresses ([Md.20] Feed 
current value) of the current stop position (start addresses) of every axes are set 
to "0". Linear interpolation positioning is then carried out from that position to a 
position at the end of the movement amount set in "[Da.6] Positioning 
address/movement amount". The movement direction is determined by the sign of 
the movement amount.   
 
• Positive movement amount .............. Positioning control to forward direction 
(Address increase direction) 
• Negative movement amount ............. Positioning control to reverse direction 
(Address decrease direction) 
 
 Restrictions 
 
(1)  The error "Continuous path control not possible" (error code: 516) will occur 
and the operation cannot start if "continuous path control" is set in "[Da.1] 
Operation pattern". ("Continuous path control" cannot be set in fixed-feed 
control.) 
(2)  "Fixed-feed" cannot be set in "[Da.2] Control method" in the positioning data 
when "continuous path control" has been set in "[Da.1] Operation pattern" of 
the immediately prior positioning data. (For example, if the operation pattern of 
positioning data No. 1 is "continuous path control", fixed-feed control cannot 
be set in positioning data No. 2.) The error "Continuous path control not 
possible" (error code: 516) will occur and the machine will carry out a 
deceleration stop if this type of setting is carried out.   
(3)   Set "1: Reference axis speed" in "[Pr.20] Interpolation speed designation 
method". The error "Interpolation mode error" (error code: 523) will occur and 
the operation cannot start if "0: Composite speed" is set.