9 - 125
Chapter 9 Major Positioning Control
9.2.22 LOOP
The LOOP is used for loop control by the repetition of LOOP to LEND.
Operation
The LOOP to LEND loop is repeated by set repeat cycles.
Positioning data setting examples
[When "LOOP" is set in positioning data No. 1 of axis 1]
Setting item Setting example Setting details
Axis 1 Positioning data No. 1
[Da.1]
Operation pattern
Setting not required. (Setting value is ignored.)
[Da.2]
Control method
LOOP Set the LOOP.
[Da.3]
Acceleration time No.
Setting not required. (Setting value is ignored.)
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/
movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP
destination positioning
data No.
[Da.10]
M code/Condition
data No./Number of
LOOP to LEND
repetitions
5 Set the LOOP to LEND repeat cycles.
[Da.20]
A
xis to be interpolated
No.1
Setting not required (setting value is ignored).
[Da.21]
A
xis to be interpolated
No.2
[Da.22]
A
xis to be interpolated
No.3
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Restrictions
(1) The error "Control method LOOP setting error" (error code: 545) will occur if a
"0" is set for the repeat cycles.
(2) Even if LEND is absent after LOOP, no error will occur, but repeat processing
will not be carried out.
(3) Nesting is not allowed between LOOP-LEND's. If such setting is made, only the
inner LOOP-LEND is processed repeatedly.