5 - 143
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
Set with a decimal.
Setting
value
K
HPR request flag OFF request
1: Turns the "HPR request flag"
from ON to OFF.
The Simple Motion module resets the value to "0" automatically
w
hen the HPR request flag is turned OFF.
(This indicates the completion of HPR request flag OFF request.)
1
0 4321+100n
Set with a decimal.
K
Manual pulse generator
1 pulse input
magnification
1 to 10000
Setting
value
1
4322+100n
4323+100n
Set with a decimal.
Setting value
Manual pulse generator enable flag
0: Disable manual pulse generator operation.
1: Enable manual pulse generator operation.
K
0 4324+100n
Set with a decimal.
K
0 to Pr.17 Torque limit setting
value (%)
Setting
value
New torque value/forward new
torque value
0 4325+100n
n: Axis No.-1