5 - 151
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
Set with a decimal.
Setting
value
Skip request
1:
K
The Simple Motion module resets the value to "0" automatically
when processing of the skip request completes.
1
Issues a skip request to have
the machine decelerate, stop,
and then start the next positioning
operation.
0 4347+100n
Set with a decimal.
Setting
value
Teaching data selection
K
0: Takes the feed current value as a positioning
address.
1: Takes the feed current value as an arc data.
0 4348+100n
Set with a decimal.
Setting value
K
Teaching
positioning
data No.
1 to 600
0 4349+100n
Set with a decimal.
Setting
value
ABS direction in degrees
K
0: Takes a shortcut.
(Specified direction ignored.
1: ABS circular right
2: ABS circular left
0 4350+100n
n: Axis No.-1