5 - 153
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
Set with a hexadecimal.
Setting
value
H
Simultaneous starting axis No.1
0 to F: Axis 1 to Axis 16
Simultaneous starting axis No.2
0 to F: Axis 1 to Axis 16
Simultaneous starting axis No.3
0 to F: Axis 1 to Axis 16
Number of simultaneous starting axes
2 to 4: 2 axes to 4 axes
0000H 4339+100n
Set with a decimal.
Setting
value
K
Speed-position switching device selection
<Speed-position switching control>
0: Use the external command signal for switching
from speed control to position control
1: Use the proximity dog signal for switching
from speed control to position control
2: Use "
Speed-position switching command" for
switching from speed control to position control
<Position-speed switching control>
0: Use the external command signal for switching
from position control to speed control
1: Use the proximity dog signal for switching
from position control to speed control
2: Use "
Speed-position switching command
" for
switching from position control to speed control
Cd.46
Cd.46
0 4366+100n
Set with a decimal.
Setting
value
K
Speed-position switching command
<Speed-position switching control>
0: Not switch from speed control to position control
1: Switch from speed control to position control
<Position-speed switching control>
0: Not switch from position control to speed control
1: Switch from position control to speed control
0 4367+100n
Set with a decimal.
Setting
value
Servo OFF command
0: Servo ON
1: Servo OFF
K
Valid only during servo ON for all axes.
0 4351+100n
n: Axis No.-1