9 - 48
Chapter 9 Major Positioning Control
Positioning data setting example
[When "1-axis fixed-feed control (fixed-feed 1)" is set in positioning data No.1 of
axis 1]
Setting item Setting example Setting details
Axis 1 Positioning data No. 1
[Da.1] Operation pattern Positioning complete
Set "Positioning complete" assuming the next positioning data
will not be executed.
[Da.2] Control method Fixed-feed 1
Set 1-axis fixed-feed control.
[Da.3] Acceleration time No. 1
Designate the value set in "[Pr.25] Acceleration time 1" as the
acceleration time at start.
[Da.4] Deceleration time No. 0
Designate the value set in "[Pr.10] Deceleration time 0" as the
deceleration time at deceleration.
[Da.6]
Positioning address/
movement amount
8000.0
m
Set the positioning address. (Assuming "mm" is set in "[Pr.1]
Unit setting".)
[Da.7] Arc address
Setting not required (setting value is ignored).
[Da.8] Command speed 6000.00mm/min
Set the speed during movement to the positioning address.
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500ms
Set the time the machine dwells after the positioning stop
(command stop) to the output of the positioning complete
signal.
[Da.10]
M code/Condition
data No./Number of
LOOP to LEND
repetitions
10
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.
[Da.20]
A
xis to be interpolated
No.1
Setting not required (setting value is ignored).
[Da.21]
A
xis to be interpolated
No.2
[Da.22]
A
xis to be interpolated
No.3
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.