9 - 50
Chapter 9 Major Positioning Control
Positioning data setting example
[When "2-axis fixed-feed control (fixed-feed 2)" is set in positioning data No. 1 of
axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2 (The required values are also set in positioning
data No. 1 of axis 2.)
Axis
Setting item
Setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
Axis 1 Positioning data No. 1
[Da.1] Operation pattern
Positioning
complete
Set "Positioning complete" assuming the next
positioning data will not be executed.
[Da.2] Control method Fixed-feed 2
Set 2-axis fixed-feed control.
[Da.3] Acceleration time No. 1
Designate the value set in "[Pr.25]
Acceleration time 1" as the acceleration time
at start.
[Da.4] Deceleration time No. 0
Designate the value set in "[Pr.10]
Deceleration time 0" as the deceleration time
at deceleration.
[Da.6]
Positioning address/
movement amount
8000.0 m 6000.0 m
Set the positioning address. (Assuming "mm"
is set in "[Pr.1] Unit setting".)
[Da.7] Arc address
Setting not required (setting value is ignored).
[Da.8] Command speed
6000.00
mm/min
Set the speed during movement. (Designate
the composite speed of reference axis speed
in "[Pr.20] Interpolation speed designation
method".)
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500ms –
Set the time the machine dwells after the
positioning stop (command stop) to the output
of the positioning complete signal.
[Da.10]
M code/Condition data
No./Number of LOOP
to LEND repetitions
10 –
Set this when other sub operation commands
are issued in combination with the No. 1
positioning data.
[Da.20]
Axis to be interpolated
No.1
Axis 2
Set the axis to be interpolated.
If the self-axis is set, an error will occur.
[Da.21]
Axis to be interpolated
No.2
– –
Setting not required (setting value is ignored).
[Da.22]
Axis to be interpolated
No.3
– –
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.