EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q Series - Page 516

Mitsubishi Electric MELSEC-Q Series
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 - 116
Chapter 9 Major Positioning Control
Positioning data setting examples
[When "position-speed switching control (forward run: position/speed)" is set in
positioning data No. 1 of axis 1]
Setting item Setting example Setting details
Axis 1 Positioning data No. 1
[Da.1] Operation pattern Positioning complete
Set "Positioning complete" assuming the next positioning
data will not be executed. ("Continuous positioning control"
and "Continuous path control" cannot be set in
"position/speed changeover control".)
[Da.2] Control method
Forward run:
position/speed
Set position-speed switching control.
[Da.3] Acceleration time No. 1
Designate the value set in "[Pr.25] Acceleration time 1" as
the acceleration time at start.
[Da.4] Deceleration time No. 0
Designate the value set in "[Pr.10] Deceleration time 0" as
the deceleration time at deceleration.
[Da.6]
Positioning address/
movement amount
10000.0
m
Set the movement amount at the time of position control
before the switching to speed control. (Assuming that the
"[Pr.1] Unit setting" is set to "mm".)
[Da.7] Arc address Setting not required. (Setting value is ignored.)
[Da.8]
Command speed 6000.00mm/min Set the speed to be controlled.
[Da.9]
Dwell time/JUMP
destination positioning
data No.
500ms
Set the time the machine dwells after the positioning stop
(command stop) by position control to the output of the
positioning complete signal. If the machine is stopped by
speed control, the setting value is ignored.
[Da.10]
M code/Condition
data No./Number of
LOOP to LEND
repetitions
10
Set this when other sub operation commands are issued in
combination with the No.1 positioning data.
[Da.20]
A
xis to be interpolated
No.1
Setting not required (setting value is ignored).
[Da.21]
A
xis to be interpolated
No.2
[Da.22]
A
xis to be interpolated
No.3
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.

Table of Contents

Other manuals for Mitsubishi Electric MELSEC-Q Series

Related product manuals