11 - 23
Chapter 11 Manual Control
When the "JOG start signal" is turned ON while the test function of
GX Works2 is used
When the "JOG star signal" is turned ON while the test function is used, it will be
ignored and the inching operation will not be carried out.
In test mode flag
ON
t
OFF
ON
OFF
Forward run inching
operation execution
Inching operation not
possible because this
is not the rising edge
of the JOG start signal
Cd.181 Forward run
JOG start
Inching operation not
possible because the test
function is being used.
Fig. 11.15 Operation when the JOG start signal is turned ON while the test function is used