13 - 33
Chapter 13 Control Sub Functions
[3] Relation between the software stroke limit function and various
controls
Control type
Limit
check
Processing at check
HPR control
Machine HPR control
Data set method
The HPR control will not be executed if the HP address
is outside the software stroke limit range.
Other than "Data
set method"
Check not carried out.
Fast HPR control
Major
positioning
control
Position
control
1-axis linear control
Checks 1) and 2) in the previous section [2] are carried
out.
For speed control: The axis decelerates to a stop
when it exceeds the software
stroke limit range.
For position control: The axis comes to an immediate
stop when it exceeds the software
stroke limit range.
2 to 4-axes axis linear
interpolation control
1-axis fixed-feed control
2 to 4-axes fixed-feed control
(interpolation)
2-axis circular interpolation
control
1 to 4-axes speed control
*1, *2
Speed-position switching control
Position-speed switching control
*1, *2
Other
control
Current value changing
The current value will not be changed if the new
current value is outside the software stroke limit range.
JUMP instruction, NOP
instruction, LOOP to LEND
Check not carried out.
Manual
control
JOG operation, Inching operation
*3
Check 1) in the previous section [2] is carried out.
The machine will carry out a deceleration stop when
the software stroke limit range is exceeded. If the
address is outside the software stroke limit range, the
operation can only be started toward the moveable
range.
Manual pulse generator operation
*3
Expansion
control
Speed-torque control
Check 1) in the previous section [2] is carried out.
The mode switches to the position control mode when
the software stroke limit range is exceeded, and the
operation immediately stops.
: Check valid
: Check is not made when the feed current value is not updated (Refer to [Pr.21]) at the setting of "feed current value"
in "[Pr.14] Software stroke limit selection" during speed control.
: Check not carried out (check invalid).
: Valid only when "0: valid" is set in the "[Pr.15] Software stroke limit valid/invalid setting".
1 : The value in "[Md.20] Feed current value" will differ according to the "[Pr.21] Feed current value during speed
control" setting.
2 : When the unit is "degree", check is not made during speed control.
3 : When the unit is "degree", check is not carried out.