13 - 36
Chapter 13 Control Sub Functions
[7] Setting when the control unit is "degree"
Current value address
The "[Md.20] Feed current value" address is a ring address between 0 and
359.99999
°
.
359.99999° 359.99999°
Fig. 13.15 Current value address when the control unit is "degree".
Setting the software stroke limit
The upper limit value/lower limit value of the software stroke limit is a value
between 0 and 359.99999
°
.
(1) Setting when the software stroke limit is to be validated.
When the software stroke limit is to be validated, set the upper limit value in a
clockwise direction from the lower limit value.
Section A
315
Set in a clockwise direction
Upper limit
Lower limit
90
Section B
(a) Set the movement range of section A as follows.
Software stroke limit lower limit value ................ 315.00000
°
Software stroke limit upper limit value ................ 90.00000
°
(b) Set the movement range of section B as follows.
Software stroke limit lower limit value ................ 90.00000
°
Software stroke limit upper limit value ................ 315.00000
°
Fig. 13.16 Software stroke limit when the control unit is "degree"