13 - 42
Chapter 13 Control Sub Functions
The following drawing shows the operation of the forced stop function.
Each operation
PLC READY signal[Y0]
All axis servo ON[Y1]
Positioning start signal[Y10]
Forced stop input
(Input voltage of EMI)
Md.50
Forced stop input
10
Forced stop
causes occurrence
Pr.82
Forced stop valid/
invalid selection
0
Forced stop valid
Md.108 Servo status
(b1: Servo ON)
ON
01
OFF
1
ON ONOFF
Forced stop
causes occurrence
Fig. 13.20 Operation for the forced stop function
[2] Wiring the forced stop
When using the forced stop function, wire the terminals of the Simple Motion
module forced stop input as shown in the following drawing. As for the 24VDC
power supply, the direction of current can be switched.
Simple Motion module
EMI
EMI.COM
24VDC
Fig. 13.21 Wiring when using the forced stop