13 - 50
Chapter 13 Control Sub Functions
(3) Add the following sequence program to the control program, and write it to
the PLC CPU.
(QD77GF starts speed change processing.)
[Speed change processing]
<Write the new speed. >
K1D108K4314H0DTOP
K1K1K4305H0TOP <Set the external command signal input
to valid.>
K1
K1K62
H0TOP
Input the external command signal.
<Set the external command function
selection to external speed change
request. >
Write 1000000 to D108 and D109.
[Program example]
M0