Chapter 13 Control Sub Functions
(2) When HPR request flag ([Md.31] Status: b3) is ON, starting Fast HPR will
result in the error "HPR request ON" (error code: 207) despite the setting
value of "[Pr.55] Operation setting for incompletion of HPR", and Fast HPR
will not be performed.
[3] Setting method of "Operation setting for incompletion of HPR"
To use the "Operation setting for incompletion of HPR", set the following
parameters using a sequence program.
Setting item
Setting
value
Setting details Buffer memory address
[Pr.55]
Operation setting
for incompletion of
HPR
Set the operation setting for incompletion of
HPR.
0: Positioning control is not executed.
1: Positioning control is executed.
87+150n
n: Axis No.-1
: Refer to Section 5.2.6 "HPR detailed parameters" for details on the setting details.