Appendix - 23
Appendices
(b) Voltage-output/Open-collector type
Make the cable within 10m (32.81ft.).
FG
(Note-1)
10126-3000PE (Connector)
10326-52F0-008 (Connector case)
DI1
DI3
DI2
DI4
DICOM
0V
(Note-2)
HA
HB
: Twisted pair cable
(Note-1): Ground FG terminal on the used equipment side. Also, connect it to the shell of connector side.
(Note-2): Be sure to connect the 0 V (-) of the manual pulse generator/incremental synchronous encoder
and the SG of the Simple Motion module.
(Note-3): The 5VDC power supply from the Simple Motion module must not be used.
Simple Motion module side
Solderless terminal
Voltage-output/open-collector type
Manual pulse generator/
incremental synchronous encoder side
External command/switching
Forced stop input
18
17
5
4
16
3
10
23
15
14
2
1
11
13
12
24
26
25
HBL
HAL
HAH
HBH
SG
(Note-2)
5V
(Note-3)
EMI
DI1
DI3
DI2
DI4
DICOM
HB
HA
SG
(Note-2)
5V
(Note-3)
EMI.COM
COM
COM
FG Shell
(Note-1)
FG
(Note-1)
EMI
EMI.COM
When using the external power supply (Recommended)