Appendix - 25
Appendices
1) The following table indicates the external input wiring cables used with
motion controller and the manual pulse generator. Make selection
according to your operating conditions.
Table 3.1 Table of wire specifications
Wire model
Core size
[mm
2
]
Number of
cores
Characteristics of one core
Finish OD
[mm]
(Note-2)
Structure
[Number of
wires/mm]
Conductor
resistance
[
/km]
Insulating
sheath OD
d[mm]
(Note-1)
20276FACBL 7/0.18mm 4P
AWG25 (0.16mm
2
)
8 (4 pairs) 7/0.18TA 115 1.0 6.8
20276FACBL 7/0.18mm 5P
AWG25 (0.16mm
2
)
10 (5 pairs) 7/0.18TA 115 1.0 7.3
(Note-1): d is as shown below.
Insulation sheath
Conductor
d
(Note-2): Standard OD. Max. OD is about 10% larger.
CAUTION
When fabricating the cable, do not make incorrect connection. Wrong connection will cause runaway or
explosion.