EasyManua.ls Logo

Mitsubishi MELSEC-Q/L - Page 511

Mitsubishi MELSEC-Q/L
850 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
509
ASIN, ASINP
1
2
3
4
4
6
7
8
7.12 Special function instructions
7.12.7 ASIN, ASINP
Program Example
(1) The following program performs a TAN operation on the angle data set by the 4 BCD digits from X20 to X2F, and stores
the results as 64-bit floating decimal point type real numbers at D0 to D3.
[Ladder Mode]
[List Mode]
[Operations involved when X20 to X2F designate a value of 135]
: SIN value of which the SIN
-1
(inverse sine) value is obtained or head number of the devices where the SIN value is stored (real number)
: Head number of the devices where the operation result will be stored (real number)
*1: Applicable for the Universal model QCPU, LCPU.
7.12.7 ASIN, ASINP Arc sine o peration on floating-point d ata (Single
precision)
7.12.7
ASIN, ASINP
Setting
Data
Internal Devices
R, ZR
J\
U\G
Zn
Constants
E
Other
Bit Word Bit Word
–– ––
*1
––
–– ––
*1
–– ––
Inputs an angle used for TAN
operation ( ).
Converts the input angle into a
64-bit floating-point real number ( ).
Converts the converted angle into a
radian value ( ).
Executes TAN operation
using the
converted radian value ( ).
1
2
3
4
Step Instruction Device
64-bit floating-point
real number
X2F
BCD value
0
D30
135
X20
Conversion
to BIN
BIN
b15
b0
BIN value
Conversion to radian
RADD
TAN operation
TAND
135
Conversion to
floating-point
FLTD
D21
135
D20D23 D22
64-bit floating-point
real number
D21
2.356194
D20D23 D22
64-bit floating-point
real number
D21
-1.000000
D20D23 D22
1
2
3
4
Process
High
performance
Redundant
Universal
LCPU
Basic
Command
Command
ASINP
ASIN
ASINP
ASIN
S
D
S D
S
D
S
D

Table of Contents