5. PARAMETERS 
5 -  8 
 
5.1.5 Extension setting 2 parameters ([Pr. PE_ _ ]) 
Operation 
mode 
Control 
mode 
No. Symbol  Name 
Initial 
value 
Unit 
Standard 
Full. 
Lin. 
D.D. 
P 
S 
T 
PE01  *FCT1  Fully closed loop function selection 1  0000h     
 
 
 
PE02    For manufacturer setting  0000h     
PE03  *FCT2  Fully closed loop function selection 2  0003h     
 
 
 
PE04  *FBN  Fully closed loop control - Feedback pulse electronic gear 1 - 
Numerator 
1   
 
 
 
PE05  *FBD  Fully closed loop control - Feedback pulse electronic gear 1 - 
Denominator 
1   
 
 
 
PE06  BC1  Fully closed loop control - Speed deviation error detection 
level 
400 [r/min]  
 
 
 
PE07  BC2  Fully closed loop control - Position deviation error detection 
level 
100 [kpulse]  
 
 
 
PE08  DUF  Fully closed loop dual feedback filter  10  [rad/s]   
 
 
 
PE09    For manufacturer setting  0000h     
PE10  FCT3  Fully closed loop function selection 3  0000h     
 
 
 
PE11  For manufacturer setting  0000h 
PE12   0000h 
PE13   0000h 
PE14   0111h 
PE15   20 
PE16   0000h 
PE17   0000h 
PE18   0000h 
PE19   0000h 
PE20   0000h 
PE21   0000h 
PE22   0000h 
PE23   0000h 
PE24   0000h 
PE25   0000h 
PE26   0000h 
PE27   0000h 
PE28   0000h 
PE29   0000h 
PE30   0000h 
PE31   0000h 
PE32   0000h 
PE33 
 
 0000h 
 
       
     
PE34  *FBN2  Fully closed loop control - Feedback pulse electronic gear 2 - 
Numerator 
1   
 
 
 
PE35  *FBD2  Fully closed loop control - Feedback pulse electronic gear 2 - 
Denominator 
1   
 
 
 
PE36  For manufacturer setting  0.0 
PE37   0.00 
PE38   0.00 
PE39   20 
PE40 
 
 0000h 
 
       
     
PE41  EOP3  Function selection E-3  0000h