14. COMMUNICATION FUNCTION 
14 -  29 
 
14.5.7 Input devices on/off (test operation) 
Each input devices can be turned on/off for test operation. However, when the device to be switched off is in 
the external input signal, also switch off the input signal. 
 
Transmit command [9] [2], data No. [0] [0], and data. 
 
Command Data No.  Set data 
[9] [2]  [0] [0]  See below. 
 
b31 b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
 
 
Bit Symbol  Bit Symbol  Bit Symbol  Bit Symbol 
0 SON  8  SP1  16   24   
1 LSP  9 SP2  17    25   
2  LSN   10  SP3   18     26   
3  TL   11  ST1   19     27  CDP 
4  TL1   12  ST2   20  STAB2   28  CLD 
5  PC   13  CM1   21     29  MECR 
6  RES   14  CM2   22     30   
7  CR   15  LOP   23     31