6. NORMAL GAIN ADJUSTMENT 
6 -  3 
 
6.2 One-touch tuning 
 
POINT 
 
When executing the one-touch tuning, check the [Pr. PA21 One-touch tuning 
function selection] is "_ _ _ 1" (initial value). 
 
 
You can execute the one-touch tuning with MR Configurator2 or push buttons. The following parameters are 
set automatically with one-touch tuning. 
 
Table 6.1 List of parameters automatically set with one-touch tuning 
Parameter Symbol  Name    Parameter Symbol Name 
PA08  ATU  Auto tuning mode    PB15  NH2  Machine resonance suppression filter 2 
PA09  RSP  Auto tuning response    PB16  NHQ2  Notch shape selection 2 
PB01  FILT  Adaptive tuning mode (adaptive filter II)    PB18  LPF  Low-pass filter setting 
PB02 VRFT   PB19 VRF11
    
Vibration suppression control 1 - Vibration 
frequency 
 
Vibration suppression control tuning 
mode (advanced vibration suppression 
control II) 
 PB20 VRF12
PB03 PST       
Vibration suppression control 1 - 
Resonance frequency 
   PB21 VRF13
 
Position command 
acceleration/deceleration time constant 
(position smoothing) 
   
Vibration suppression control 1 - Vibration 
frequency damping 
PB06  GD2  Load to motor inertia ratio    PB22  VRF14
PB07  PG1  Model loop gain       
Vibration suppression control 1 - 
Resonance frequency damping 
PB08  PG2  Position loop gain    PB23  VFBF  Low-pass filter selection 
PB09  VG2  Speed loop gain    PB47  NHQ3  Notch shape selection 3 
PB10  VIC  Speed integral compensation    PB48  NH4  Machine resonance suppression filter 4 
PB12  OVA  Overshoot amount compensation    PB49  NHQ4  Notch shape selection 4 
PB13  NH1  Machine resonance suppression filter 1    PB51  NHQ5  Notch shape selection 5 
PB14  NHQ1  Notch shape selection 1    PE41  EOP3  Function selection E-3 
 
6.2.1 One-touch tuning flowchart 
(1)  When you use MR Configurator2 
Make one-touch tuning as follows. 
 
 
 
 
Startup a system referring to chapter 4. 
 
 
 
Rotate the servo motor by an external controller, etc. (The one-touch tuning cannot be performed if the 
servo motor is not operating.) 
 
 
Start one-touch tuning of MR Configurator2. 
 
 
 
Select a response mode (high mode, basic mode, and low mode) in the one-touch tuning window of 
MR Configurator2. 
 
 
Start
Startup of the system
Operation
One-touch tuning start
Response mode selection
One-touch tuning execution
End
 
Push the start button to start one-touch tuning. Push it during servo motor driving. 
When one-touch tuning is completed normally, the parameters described in table 6.1 will be set 
automatically.